Related PDF

A 1
Montgomery County Stations and Test Types Offered as of
Participating stations post the retail price charged to customers for the emission test including
Dental Provider Manual -
Transfer the relinquishing of responsibility for the continuing care of
UAV DATA ACQUISITION IN AUSTRALIA AND NEW ZEALAND USER
UAV DATA ACQUISITION IN AUSTRALIA AND NEW ZEALAND USER NEEDS REPORT Dr Sam Amirebrahimi
InvisiBrake Reference Information - Roadmaster Inc.
Questions Comments Call ROADMASTER Customer Service at 1 800 669 9690 InvisiBrake Reference Information Please note this
24580
24580 24581 24582 49047 49073 49199 49257 49258 49264 49327 Absorbent Filter Absorbent Filter
Guardian Engine Kit s -
GUARDIAN ENGINE KIT GUIDELINES 1 ORDERING Specify part number make model year and cubic
Single-Molecule Fluorescence Imaging Techniques for the
Single Molecule Fluorescence Imaging Techniques for the Detection of Reactive Oxygen Species T Tachikawa and
Class Schedule 3/15/2019 thru 8/22/2019 - St. Cloud State
Class Schedule 3 15 2019 thru 8 22 2019 1 Minneapolis and Suburbs Our websiteMnSafetyCenter org Andover Sr Center
RNA Isolation with Trizol Reagent - NAU
1 RNA Isolation with Trizol Reagent 1 ml Trizol using small amount of tissue
201901 ARF14264 PEAK FULL SYN MV DEX VI-MERC LV ATF Spec
PRODUCT INFORMATION Test Method SHIPPING INFORMATION UID F Appearance ASTM D 1500 Viscosity Index ASTM
Markt / Belfort / Breidelstraat r 8 ozenhoedkaai
Markt Belfort Breidelstraat 1 The market square is the heart of the
CARPROG Toyota immo manual - codecard
All right reserved www codecard lt 6 Use only original factory key With Silca 4D transponder
SOFTWARE UPGRADE VEHICLE COVERAGE GUIDE
SOFTWARE UPGRADE Video Coverage guide Personality keys 18 4 Model Year updates What
THE CODE OF HAMMURABI -
PROLOGUE When Anu the Sublime King of the Anunaki and Bel the lord of
Problem Diagnosis Avocado 1-20-11 final - UCANR Web Sites
PROBLEM DIAGNOSIS FOR AVOCADO 3 What the Problem Looks Like Probable Cause Control Measures
Image Processing with ImageJ -
search areas from nanotechnology to as tronomy It is common practice for manufactur ers of image
ESI[tronic] Onlineupdate New systems in Onlineupdate 2019/1
ESI tronic Onlineupdate New systems in Onlineupdate 2019 1 01 Vehicle Brand System Group System System Version
Table of Contents Reading Your Dupli-Color Guide
Dupli Color for Best Results Special Finishes Primers 3 Use Primers Stock No Prime
Amsoil filter application style height od thread gasket
EA15K01 Various Scion Toyota Lexus 08 19 Pontiac Vibe 09 10 Cartridge 2 31 2 48 1 13 N A N A
Keys and adapters reference chart - Snap-on
67 67 Keys and adapters reference chart 10 4 9 4 8 4 7 4 6 4 4 4 4 1
Engine VIN Codes - Amsoil
Engine Codes At times a vehicle manufacturer may use engines of the same size
SERVICE PRO PREMIUM GLOBAL FULL SYNTHETIC MULTI- VEHICLE ATF
SERVICE PRO PREMIUM GLOBAL FULL SYNTHETIC MULTI VEHICLE ATF Service
African Organic Agriculture Training Manual - Citrus
African Organic Agriculture Training Manual Module 09 Crops Unit 21 Citrus CONTENTS 1 Introduction
Event Data Recorder - Reference Document
Page 1 Event Data Recorder Reference Document An Event Data Recorder EDR
Agilent OpenLAB CDS
This document provides a listing of the major feature modifications made in each release
Service Pro - Oil Filters
Part Number Popularity Principle Application CHAMP FRAM MIGHTY NAPA PUROLATOR Service Pro Oil
PDF COLLEGE GRADS WELCOME HERE Toyota Toyota Official
LEARNING IS EARNING Turn your degree into a hard earned rebate LET THE SAVINGS COMMENCE
OEM DIAGNOSTIC SCANNING POSITIONS QUICK REFERENCE CHART w
OEM DIAGNOSTIC SCANNING POSITIONS QUICK REFERENCE CHART The full Position Statements are available at

Popular PDF

SCION 456-GC Specification Sheet

Available traps Two lengths A wide range of standard packing and custom packings Detector Options Maximum detectors two operating concurrently one of which is

Insert your error message here, if the PDF cannot be displayed.



File type: PDF

File size: 386,52 KB

File name: SCION-456-Specfication-Sheet-1.pdf


	Speci�ca�on Sheet
Height: 57 cm (22.5 in.), 
Depth: 56 cm (22.0 in.) 
Weight*: 43 kg (59lb)
* Typical values
Environmental Condi�ons
Opera�ng temperatures: 10°C to 40°C.            
Line voltage requirements: 120 V, 230 V (±10% nominal)
Column Oven
Temperature range:
Ambient: +4°C to 450°C 
: -100°C to 450°C 
Liquid CO
: -60°C to 450°C
Temperature program ramps/holds: 24/25             
Maximum temperature ramp rate:  
150°C/min for all voltages and 180°C/min with insert accessory
Cool down rate: 400 °C to 50 °C in 4.5 minutes 
Temperature set-point resolu�on: 0.1 °C
ambient temp.
Reten�on Time Repeatability <0.008% or < 0.0008 min, based on 
n-Pentadecane under temperature programming condi�ons.
Area repeatability < 1% RSD
General Speci�ca�ons                                                             
Up to 9 EFC modules total, injector, detector and auxiliary Op�onal 
External events (digital output):
8 standard
8 op�onal, total 16     
Max number of �med events:  30 #
Heated zones:
Standard 9                               
Two power outlets 24V (1A max. each)
Temperature Range (°C)
456-GC Rates  (°C/min)
SCION Instruments
1 Bain Square, Kirkton Campus
Livingston, UK EH54 7DQ 
For research use only. Not for use in diagnos�c procedures. 
www.scioninstruments.com
Methods:                                                                                                                    
Maximum stored internal methods: 50 (max. 30 alphanumeric characters)
Logging: 
Run log �le (stored with the chromatogram when using CompassCDS) Error log �le
Local Display:                             
TFT full color screen  
WVGA resolu�on (800 x 480) Size 23 cm (9”)
Local Control:
Touch screen
Hard Keys
Languages: 
English, German, French, Spanish, Italian, Portuguese, Cyrillic, Kanji, Chinese (standard and tradi�onal), Thai, Korean 
and Dutch
Local automa�on: 
Method lines: 25 
In�nite looping
Dual and duplicate injec�on
Communica�on 
Ethernet: Protocol: TCP/IP 
Data rate: 100 Mbps
Control: 
GC control and method parameters 
Analog output (op�onal):
- Time programmable steps: 30             
- Output so�ware selectable (set individual):
0-1 V (default)
Synchroniza�on signals with other devices and data systems: 
Ready in and out
Start in and out
Data Handling and System Control: 
CompassCDS Chromatography Data System
Cer��ca�ons
CSA:
IEC: 61010-1 
ATEX Direc�ve 94/9/EC
SCION Instruments
1 Bain Square, Kirkton Campus
Livingston, UK EH54 7DQ 
For research use only. Not for use in diagnos�c procedures. 
www.scioninstruments.com
Injector Op�ons    
Maximum injectors: two, opera�ng concurrently.
Pneuma�cs: Electronic Flow Control (EFC):
S/SL Split/Splitless injector*
PTV Programmable Temperature 
Vaporizing* COC Cold On-Column injector*
Flash injector
PWC Packed/ Wide bore On-Column injector
* including septum purge
S/SL Split/Splitless Injector 
Pressure range: 0-150 psi 
Total �ow:
500 mL/min for N2/Ar 
1500 mL/min for He/H2
Maximum temperature: 450°C
Split range: 1-10,000 (column dependent)
Suited for columns:
Wide bore: (0.53 mm)     
Narrow bore: (0.05 to 0.32 mm)
COC Cold On-Column Injector 
Pressure range: 0-150 psi              
Total Flow: 50 mL/min (Type 23 EFC)
Temperature range:                       
Ambient +10 °C to 450 °C using air cooling
-60 °C to 450 °C using liquid CO
 cooling
-160 °C to 450 °C using liquid N
  cooling
Maximum temperature: 450 °C          
Maximum temperature ramp rate: 200 °C/min 
Temperature ramps/holds: 24/25
Suited for columns:   
Wide bore (0.53 mm) 
Narrow bore (0.32mm)
PTV Programmable Temperature
Vaporizing Injector             
Pressure range: 0-150 psi        
Total �ow:
500 mL/min for N2/Ar
1500 mL/min for He/H2
SCION Instruments
1 Bain Square, Kirkton Campus
Livingston, UK EH54 7DQ 
For research use only. Not for use in diagnos�c procedures. 
www.scioninstruments.com
Temperature range:                                         
Ambient + 10 °C to 450°C using air cooling
-160 °C to 450 °C using liquid N
 cooling
-60 °C to 450 °C using liquid CO
 cooling
Maximum temperature ramp rate: 200°C/min 
Temperature ramps/holds: 24/25
Split range: 1-10,000 (column dependent)
Opera�onal capabili�es:   
Large volume injec�on 
Temperature ramped splitless 
Cold on-column                   
Suited for columns:             
Wide bore (0.53 mm)     
Narrow bore (0.05 to 0.32 mm)
Maximum injec�on volume: 250 µL (LVI mode)
Flash Injector 
Pressure range: 0-150 psi 
Total �ow: 50 mL/min (Type 23 EFC)
Maximum temperature: 450°C Suited for columns:
Wide bore (0.53 mm) 
Packed (1/8” to 1/4”)
PWOC Packed/Wide-bore On-Column Injector
Pressure range: 0-150 psi 
Total �ow: 50 mL/min (Type 23 EFC) 
Maximum temperature: 450°C
Suited for columns:  
Wide bore (0.53 mm) 
Packed (1/8” to 1/4”)
Electronic Flow Control: Injectors (EFC)     
Module types: 4 injector-speci�c modules               
Pressure: 0.1 % Full Scale                                              
Resolu�on pressure set points is 0.001psi                         
Flow sensor accuracy 2% of measured or 0.2% of full scale 
Flow sensor repeatability 0.5%
Sample Preconcentra�on Trap (SPT)
Trace level analysis of vola�les in gases
Fully integrated
Temperature Range:
-60°C to 450°C using liquid CO
cooling
°C to 450°C using liquid N
 cooling
Temperature rate:
Ballis�c for instant release of adsorbed vola�les
SCION Instruments
1 Bain Square, Kirkton Campus
Livingston, UK EH54 7DQ 
For research use only. Not for use in diagnos�c procedures. 
www.scioninstruments.com
Available traps:
Two lengths
A wide range of standard packing and custom packings
Detector Op�ons 
Maximum detectors: two, opera�ng concurrently (one of which is 
a Single or Triple Quad MS)         
Pneuma�cs: Electronic Flow Control (DEFC) 
Detector types: 
FID Flame Ioniza�on Detector 
TCD Thermal Conduc�vity Detector              
ECD Electron Capture Detector NPD 
NPD Nitrogen-Phosphorus Detector           
PFPD Pulsed Flame Photometric Detector
PDHID Pulsed Discharge Helium Ioniza�on Detector          
MS Mass Spectrometry (see GC/MS brochure and datasheet)
Note:  Data Acquisi�on Rate: 600Hz for all detectors, (excep�on 
FID Flame Ioniza�on Detector 
Maximum temperature: 450 °C 
Detec�vity: 1.4 pg C/sec         
Linear dynamic range: 10 7
Flame �p type: ceramic (patented) Opera�onal quality:
Flame-out detec�on 
Auto re-igni�on
TCD Thermal Conduc�vity Detector 
Maximum temperature: 450 °C Detec�vity: 300 pg/mL (Butane) 
Linear dynamic range: 10
Opera�onal quality:
Filament protec�on 
Automa�c bridge balancing
ECD Electron Capture Detector 
Maximum temperature: 450°C  
Detec�vity: 7 fg/s Lindane                        
Linear dynamic range: 10
Radioac�ve source: 63Ni - 15 mCi (555 Mbq)
NPD Nitrogen-Phosphorus Detector 
Maximum temperature: 450°C 
Detec�vity:
N: 100 fg N/sec (Azobenzene) P: 100 fg P/sec (Malathion)
Linear dynamic range: 
Opera�onal quality: self-aligning bead
SCION Instruments
1 Bain Square, Kirkton Campus
Livingston, UK EH54 7DQ 
For research use only. Not for use in diagnos�c procedures. 
www.scioninstruments.com
PFPD Pulsed Flame Photometric Detector
Photomul�plier tube: 
S/P/N                            
Maximum temperature: 450 °C
Detec�vity: 
S: 1 pg S/sec (S/P tube)
P: 100 fg P/sec (S/P tube)  
N: 20 pg N/sec (S/P/N tube)
Linear dynamic range: 
Up to 23 elements can be detected
PDHID Pulsed Discharge Helium Ioniza�on Detector Detec�vity:
50 ppb (Methane)
Linear dynamic range: 10
 (Methane)
Opera�onal quality:
Gold plated connec�ons 
Welded column connec�ons
Detectors (DEFC)
Module types: 6 detector-speci�c modules
Accuracy: ± 7 % set point �ow 
Resolu�on: 0.1 or 1 mL/min
Automa�on Op�ons
8410 Autoinjector
Sample capacity:
Large solvent wash vial: 2 x 120 mL*
Dual and duplicate mode 
Internal standard addi�on
Modes of opera�on: 
Ambient headspace*
SPME (Solid Phase Micro Extrac�on)* 
Sample hea�ng and cooling*
Pre-programmed modes of injec�on Syringes: 
1 μL, 2 μL, 5 μL, 10 μL, 100 μL, 250 μL for liquid injec�on
SCION Instruments
1 Bain Square, Kirkton Campus
Livingston, UK EH54 7DQ 
For research use only. Not for use in diagnos�c procedures. 
www.scioninstruments.com
8400 Autosampler
Sample capacity: 100 x 2 mL vials 
Large solvent wash vial: 2 x 120 mL* 
Dual and duplicate mode      
Internal standard addi�on
Modes of opera�on: 
Ambient headspace* 
Sample hea�ng and cooling*
Pre-programmed modes of injec�on
Syringes:
1μL, 2 μL,5 μL,10 μL,100 μL,250 μL for liquid injec�on
* Op�onal
Op�onally a CTC-PAL autosampler, including speci�c op�ons 
may be installed.
SCION Instruments
1 Bain Square, Kirkton Campus
Livingston, UK EH54 7DQ 
For research use only. Not for use in diagnos�c procedures. 
www.scioninstruments.com